IADR 95th
24/75

-24-G-CEM Capsule, G-CEM LinkAce1386 Effect of Dispensing Systems on Mechanical Properties of Resin-Based CementsPoster Presentation3:45 PM–5:00 PM Mar 23, 2017CC, First Floor Authors:Authors:TaiseerSulaiman(Presenter)School of Dentistry, University of North CarolinaAwabAbdulmajeed, School of Dentistry, University of North CarolinaAli Altitinchi, School of Dentistry, University of North CarolinaSumithaAhmed, School of Dentistry, University of North CarolinaTerence Donovan, School of Dentistry, University of North CarolinaAbstract: Abstract: Objectives: The purpose of this study is to examine how the mechanical properties of each cement differs with changes in the dispensing system.Methods: Resin-based cement specimens: PANAVIA SA Cement Plus Handmix, PANAVIA SA Cement Plus Automix(Kuraray); RelyXUnicemHandmix, RelyXUnicem2 Automix(3M); G-CEM Capsule Automix, G-CEM LinkAceAutomix(GC America); VariolinkII Handmix, VariolinkEsthetic Automix(Ivoclar), were prepared for each mechanical test and examined after thermocyclingfor 10,000 cycles to the following: Compressive Strength (CS) (ISO 9917-1), DiametralTensile Strength (DTS), Fracture toughness (FT) (ISO standard 6872; Single edge V-notched beam Strength (DTS), Fracture toughness (FT) (ISO standard 6872; Single edge V-notched beam method). Specimens were mounted and loaded at a crosshead rate of 1 mm/min (0.5 mm/min for FT) with a universal testing machine until failure occurred. One-Way ANOVA was used to analyze data for statistical significance.Results: There was a statistical significance between the mechanical properties of the cements when comparing between the dispensing method. See table for results.Conclusions: Changing the dispensing method may alter the mechanical properties of resin-based cements. Easier is not always better. Clinical significance of these results are yet to be based cements. Easier is not always better. Clinical significance of these results are yet to be determined.Table(s):RelyXUnicem(Handmix)RelyXUnicem 2(Automix)Variolink II(Handmix)VariolinkEsthetic(Automix)PANAVIASA(Handmix)PANAVIASA(Automix)G-CEMCapsule(Automix)G-CEMLinkAce(Automix)FT (MPa.m1/2)0.780.811.05*0.70.80.760.441.03*CS (MPa)133160*202*169154196*124159*Disclosure Statement:The submitter must disclose the names of the organizations with which any author have a relationship, the nature of the relationship, and the clinical or research area involved. The following is submitted: NONEI have read the IADR policy on licensing.Signed by TaiseerSulaimanCS (MPa)133160*202*169154196*124159*DTS (MPa)384039432944*3148*Signed by TaiseerSulaimanReprinted with permission from the Journal of Dental Research, J Dent Res 96 (Spec Iss A):-24-abstract number 1386, https://iadr2017.zerista.com/event/member/330835, 2017

元のページ  ../index.html#24

このブックを見る